Vista de página 177
165
O
p
eration Descri
p
tion XML exam
p
le
edit-config:
error-option
Determines the action to take in
case of a configuration error.
The error-option element has
one of the following values:
stop-on-error—Stops the
operation on error and
returns an error message.
This is the default
error-option value.
continue-on-error—Continue
s the operation on error and
returns an error message.
rollback-on-error—Rolls back
the configuration. This value
is not supported by the
current software version, and
it is reserved for future use.
To issue the configuration for two interfaces with the
error-option element value as continue-on-error:
<rpc message-id ="101"
xmlns="urn:ietf:params:xml:ns:netconf:ba
se:1.0">
<edit-config>
<target>
<running/>
</target>
<error-option>continue-on-error</error-o
ption>
<config
xmlns:xc="urn:ietf:params:xml:ns:netconf
:base:1.0">
<top
xmlns="http://www.h3c.com/netconf/config
:1.0">
<IF xc:operation="merge">
<Interfaces>
<Interface>
<IfIndex>262</IfIndex>
<Description>222</Description>
<ConfigSpeed>100000</ConfigSpeed>
<ConfigDuplex>1</ConfigDuplex>
</Interface>
<Interface>
<IfIndex>263</IfIndex>
<Description>333</Description>
<ConfigSpeed>100000</ConfigSpeed>
<ConfigDuplex>1</ConfigDuplex>
</Interface>
</Interfaces>
</Ifmgr>>
</top>
</config>
</edit-config>
</rpc>