Installing FRUs
Installing an interface module
The methods for installing NSQ1GT2UA0, NSQ1GP4U0, and NSQ1XS2U0 are similar. The following
example installs the NSQ1XS2U0 to the F1000-A-EI.
IMPORTANT:
NSQ1XS2U0 can be installed to only slot 1. NSQ1GT2UA0 and NSQ1GP4U0 can be installed to either
slot 1 or slot 2.
To install an interface module:
1. Locate the slot to install the interface module.
2. Loosen the fastening screws on the filler panel with a Phillips screwdriver to remove the filler
panel.
If you cannot remove the filler panel, use a flat-blade screwdriver to pry the filler panel up to
remove it.
Put the removed filler panel and screws in an antistatic bag for future use.
Figure 16 Removing the filler panel
3. Push the interface module with its components facing upwards along the guide rails into the slot.