Figure 9 Attaching cable management brackets to an M9006 gateway
(1) Place the cable management bracket against the installation position on the chassis
(2) Screw holes for installin
g
the cable mana
g
ement bracket
(3) Screws for attachin
g
the cable mana
g
ement bracket to the chassis
(4) Power cable management bracket
Installing mounting brackets
Before installing the gateway to the rack, install the mounting brackets to the chassis. Marks L and R are
printed inside the mounting brackets to distinguish between the left and right mounting brackets. To
install the mounting brackets, face the front of the gateway, and attach the left and right mounting
brackets to the two sides of the gateway, as shown in Figure 10.
Figure 10 Installing the
mounting brackets to an M9006 gateway
(1) Screws for attaching the mounting brackets to the chassis (2) Mounting brackets
(3) Si
g
nal cable mana
g
ement brackets
Installing air filters (optional)
Air filters are installed at the air inlet vents to prevent dust from entering the chassis. If you have ordered
air filters, install the air filters before mounting the gateway to the rack.